1. Ensure that the coating equipment is installed horizontally, the grounding wire should be installed, and the independent leakage switch should be installed for safe use.
2. Keep the coater clean, use compressed air machine to clean the dust inside and outside the shell, thread debris and so on before starting up every day.
3. Hard objects (scissors, pens, rulers, tools, etc.) shall not be placed on the worktable and outer cover plate, so as not to be damaged by the conveyor belt.
4. Start the machine by pressing the power on first, set the temperature at 50 ~ 60 ℃ first, do not exceed 80 ℃ (realize the complete separation of upper and lower belts before speed regulating the conveyor belt) adjust the required temperature again. The speed, temperature and pressure can be adjusted freely according to the operation requirements.
5. Do not stop the machine suddenly when it is running at high temperature. In case of this emergency, use the manual device to rotate the conveyor belt slowly to prevent the conveyor belt from being damaged due to high temperature.
6. Clean the conveyor belt regularly (use the special detergent matching with the original factory to ensure the long service life of the conveyor belt): A. clean the conveyor belt once every 4 hours when the glue is sticking and permeating seriously; B. clean the conveyor belt once before shutdown.
7. Fill lubricating oil (high temperature grease) into the transmission parts and bearings of the coater regularly every day to ensure the long-term smooth operation of the coater.
8. If the coater moves to the original position after installation, be sure to adjust the level to prevent uneven pressure or belt deviation and damage.
9. When sticking and ironing, please try your best to make the upper piece smaller than the lower piece, and the width of the cloth piece shall not be greater than the width of the coater, otherwise it may affect the sticking and ironing, the conveyor belt deviation or the coater running and stopping.
10. After use, before shutdown, the pressure must be adjusted to no pressure state, turn off the heating system, maintain the conveyor belt, and then set the delay cooling or automatic shutdown.
Coating machine maintenance knowledge 2: conveyor belt maintenance
(Summary description)Coating machine maintenance knowledge 2: conveyor belt maintenance
1. Ensure that the coating equipment is installed horizontally, the grounding wire should be installed, and the independent leakage switch should be installed for safe use.
2. Keep the coater clean, use compressed air machine to clean the dust inside and outside the shell, thread debris and so on before starting up every day.
3. Hard objects (scissors, pens, rulers, tools, etc.) shall not be placed on the worktable and outer cover plate, so as not to be damaged by the conveyor belt.
4. Start the machine by pressing the power on first, set the temperature at 50 ~ 60 ℃ first, do not exceed 80 ℃ (realize the complete separation of upper and lower belts before speed regulating the conveyor belt) adjust the required temperature again. The speed, temperature and pressure can be adjusted freely according to the operation requirements.
5. Do not stop the machine suddenly when it is running at high temperature. In case of this emergency, use the manual device to rotate the conveyor belt slowly to prevent the conveyor belt from being damaged due to high temperature.
6. Clean the conveyor belt regularly (use the special detergent matching with the original factory to ensure the long service life of the conveyor belt): A. clean the conveyor belt once every 4 hours when the glue is sticking and permeating seriously; B. clean the conveyor belt once before shutdown.
7. Fill lubricating oil (high temperature grease) into the transmission parts and bearings of the coater regularly every day to ensure the long-term smooth operation of the coater.
8. If the coater moves to the original position after installation, be sure to adjust the level to prevent uneven pressure or belt deviation and damage.
9. When sticking and ironing, please try your best to make the upper piece smaller than the lower piece, and the width of the cloth piece shall not be greater than the width of the coater, otherwise it may affect the sticking and ironing, the conveyor belt deviation or the coater running and stopping.
10. After use, before shutdown, the pressure must be adjusted to no pressure state, turn off the heating system, maintain the conveyor belt, and then set the delay cooling or automatic shutdown.
- Categories:Industry News
- Author:
- Origin:
- Time of issue:2020-12-23
- Views:0
Scan the QR code to read on your phone
News
Contact Info
Address: Keyun Road, Industrial Transfer Park, Shantou City, Haojiang District, Shantou City, Guangdong Province
Tel:400-880-6066
Fax:+86-0754-88226282
E-mail:sales@hyspe.com
Mobile website
Copyright © 2021 Shantou Huaying Converting Equipment ltd. 粤ICP备2020125445号 Powered by:www.300.cn